WECOMXB 5 EN81-20 Elevator Light Curtain
1.Performance Parameter
NO. |
Items |
Performance Parameter |
1 |
Dimension |
A B C L Q T (Choose one aluminum profile from them, if you need L profile, the model will be: WECOMXB L5) |
2 |
Infra red dioeds range |
47.5mm |
3 |
Minimum detecting objection |
≤50mm (meet EN81-20 standard) |
4 |
Number of Infra red diode |
36 Pair Diodes |
5 |
Scanning beams |
106-174beams |
6 |
The highest detecting range |
1665mm (meet EN81-20 standard) |
7 |
The lowest detecting range |
20mm (meet EN81-20 standard) |
8 |
Detecting range |
0~4000mm |
9 |
Response time |
≤65ms |
10 |
Recovery time |
≤1.5s |
11 |
Vertical tolerance |
±15mm/7° |
12 |
Horizontal tolerance |
±3mm/5° |
13 |
Output mode |
1NO+1NC capacity 120VAC 1A |
14 |
Working voltage |
185—290VAC |
15 |
Protection level |
IP54 |
16 |
Light immunity |
>100,000LUX |
17 |
EMC |
EN12015, EN12016 |
18 |
LED Interpretation |
1)Red LED is light in receiver when shielded |
19 |
Powered LED Interpretation |
1)Yellow LED indicator is in receiver |
2.Beams Designing And Connection System
TX & RX distance less than 400 mm, it is 106beams; TX & RX distance more than 400 mm, it is 174beams.
WECOMXB 5 SERIES elevator door detector photocell conform to the Number of 1~3 of EN 81-20 European standard.The details are:
1)The protective device shall cover the opening over the distance between at least 25mm and 1600mm above the car door sill;
2)The protective device shall be capable of detecting obstacles minimum of 50mm diameter;
3)The protective device may be rendered inoperative in the last 20mm of door closing
Related Information:
Elevator maintenance of security and technical points(7/10)
In addition, although currently more lift lock loop normal, but also pull the door lock relay, but usually in the door to take a pair of normally open relay contacts and then sent to the computer (or PC) for testing, if the door lock relay contact itself poor state of lock circuit will cause failure.
Safety Edge (photoelectric door, door curtains)
Role:
In order to prevent the passengers caught in elevator doors closing process, it is generally in the elevator door sedan equipped with a safety touch pad (or photoelectric or light curtains).
Safety Edge: one device for mechanical pinch, when the elevator in the closing process, the people met safety edge, safety edge indented, led lower part of a micro switch, safety edge switching, control direction of rotation to open the door...
Related Products: